| SPECIFICATION | |||||||
| Output | SPEC MODEL NO. | VP-0502000 | VP-0901200 | VP-1201000 | VP-1201500 | VP-1801000 | VP-2400750 |
| DC VOLTAGE | 5V | 9V | 12V | 12V | 18V | 24V | |
| RATED CURRENT | 2A | 1.2A | 1A | 1.5A | 1.0A | 0.75A | |
| CURRENT RANGE | 0-2.0A | 0-1.2A | 0-1A | 0-1.5A | 0-1.0A | 0-0.75A | |
| RATED POWER | 10W | 12W | 12W | 18W | 18W | 18W | |
| RIPPLE & NOISE(MAX) | 1% | 1% | 1% | 1% | 1% | 1% | |
| VOLTAGE TOLERANCE | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | |
| LINE REGULATION | 1% | 1% | 1% | 1% | 1% | 1% | |
| LOAD REGULATION | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | |
| SETUP,RISE,HOLD UP TIME | 300ms, 50ms, 12ms/230VAC 1300ms, 50ms, 12ms/115VAC at full load | ||||||
| Input | VOLTAGE RANGE | 100-240V AC | |||||
| FREQUENCY | 50/60HZ | ||||||
| EFFICIENCY | 81.5% | 83.5% | 83.0% | 84.0% | 85.0% | 85.5% | |
| AC CURRENT | 0.5A / 115VAC 0.3A / 230VAC | ||||||
| INRUSH CURRENT (max.) | COLD START 30A / 115VAC 60A / 230VAC | ||||||
| LEAKAGE CURRENT (max.) | 0.25mA / 240VAC | ||||||
| Protection | OVER LOAD | 110 ~ 200% rated output power | |||||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
| OVER VOLTAGE | 110 ~ 140% rated output voltage | ||||||
| Protection type : Clamp by zener diode, output short | |||||||
| ENVIRONMENT | WORKING TEMP. | 0 - +50℃ | |||||
| WORKING HUMIDITY | 20% ~ 90% RH non-condensing | ||||||
| STORAGE TEMP., HUMIDITY | -20 - +85℃,5 to 95% RH | ||||||
| TEMP. COEFFICIENT | 0.03% /°C(0 ~ 40℃ ) | ||||||
| VIBRATION | 10-500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
| SAFETY & EMC | SAFETY STANDARDS | EN-60950-1 , IEC 60950-1 Approval | |||||
| WITHSTAND VOLTAGE | I/P-O/P:4242VDC | ||||||
| ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ℃ | ||||||
| EMC EMISSION | Compliance to EN55022 class B, EN61000-3-2,3, FCC part15 class B | ||||||
| EMC IMMUNITY | Compliance to EN61000-3-2,3 | ||||||
| OTHERS | MTBF | 780Khrs min. MIL-HDBK-217F (25 ) | |||||
| DIMENSION | 75.0*28.0*39.0mm | ||||||
| PACKING | 90g/pc; 100pcs/carton | ||||||
| CONNECTOR | PLUG | See page 2 ; Other type available by customer requested | |||||
| CABLE | See page 2 ; Other type available by customer requested | ||||||
| NOTE | 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Tolerance: includes set up tolerance, line regulation, load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation is measured from 10% to 100% rated load. 6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification provided by the IC manufacturer. | ||||||